In the ALMA LO, for reasons of simplicity and reliability it has been specified that mechanical tuners will not be employed. This is a departure from designs traditionally used in total power radio telescopes. As a paradigm, consider the NRAO12m. Since the demise of Klystrons, the ultimate LO source was a Gunn diode, probably made by John Carlstrom. This device could be tuned, rejecting noise in the LO signal to a very high degree. At higher frequencies, the Gunn was located in series with multipliers, also tunable, sometimes vexingly so. John Payne estimates: " It is instructive to calculate both the intensity and stability of any spurious signals that may accompany the LO. A few assumptions are needed. Make the following: the minimum bandwidth is 100 KHz: the position switching time is 30 secs: the LO power required is 0.5 micro Watts: the bandwidth of the LO signal is 1 Hz and any spurious signals in the bandpass are stable to better than one part in one thousand over one minute( the usual position switching cycle). This latter point establishes the residual amplitude of any spurious signals in the I.F. passband to be around one Kelvin. Of course a crucial point here is the bandwidth of the spurious signal. If the same as the LO its intensity will be lessened by a factor of 10E5 by the resolution of the spectrometer. The strength of the LO signal in Kelvin is around 10E16 so any spurious signal for this very simple scenario should be around 160dB down on the LO signal." Now consider ALMA. There is no mechanical tuning of the YIG oscillator, so noise in the LO signal is not rejected but passes to the amplifiers and multiplier(s). Thacker notes that the YIG itself is very clean but operates at intrinsically lower frequencies than does a Gunn. Owing to this, more amplification and multiplication must be included to reach the very high ALMA frequencies. Within the YIG, all those heavy nuclei precessing in lockstep make a very good resonator which has the advantage of being electrically tunable but still a tuned resonator which rejects noise just as the mechanical resonator in the Gunn. The multiplier is not tunable either, and passes noise not only in the desired harmonic but perhaps in others as well, From spectrum analyzer observations, it is known that this noise is present and it can be roughly characterized in bandwidth and strength but not as well in temporal stability. If this noise is injected early in the signal chain, it is subject to further instability in any amplification as even a perfectly stable signal will have superposed upon it gain fluctuations from the amplifying device. The same gain fluctuations are affecting the system noise and the astronomical signal, so the spur does not necessarily make things any worse, as Larry notes. How are we to know whether the ALMA total power system will be capable of the science tasks assigned to it? It is planned to test this system as completely as possible using an ALMA Front End in conjunction with the Green Bank Spectrometer. This test will take place in late May or early June and involve many of the elements of a complete ALMA system. Skip Thacker will carry out this test, accompanied by someone from the science group (AW). This test will not include a laser synthesizer; the 100 GHz signal will come from a harmonic multiplier as traditionally provided as a clean test is needed. Skip plans to set the system up and integrate for several hours to reach levels of several mK with spectral resolution provided by the spectrometer in its widest spectral mode, a few hundred kHz. The system will be switched, so a non-stable signal will show up as a spectral feature within the bandpass. The result of the test will be a demonstration that the ALMA LO can provide stable clean signals down to a level which will be determined. If the system provides a clean bandpass down to the several mK level, it is still possible that the output of the multiplier produces power at multiples of the desired frequency. This should be characterized also, by a future test. A further worry is that the LO from the WVR, at 183 GHz, will also provide an unwanted harmonic at 366... GHz which may affect some receivers. This will also be characterized when the system becomes available.