Responses to Dick Crucher's points on the ALMA receiver design LRD 2001-01-03 (Numbered sections correspond to similarly numbered points in Dick's notes.) 1. The suggestion that half the antennas should be deliberately cross-polarized by 3 dB with respect to the others seems very strange. This creates an asymmetry in the array that will produce a wide range of problems, not just for polarization measurements. Dick claims that it's an "established method" but he fails to cite any references. We need a detailed explanation of how it is supposed to work. I certainly question whether there is any advantage at all with respect to alternatives. OTOH, if it is somehow established that it's desirable to orient half the antennas at 45d polarization angle with respect to the others, then it is probably feasible to do this for *some* bands. Bands with more complicated optics within the cartridge cannot be different among antennas, but simpler ones might be. We can keep this possibility in mind during detailed design, but I would ask that the justification for doing so be worked out first. 2. It is not true that the recommendation for polarization optimization was ignored. On the contrary, it was carefully considered and every effort was made to minimize the beam squint. However, it was found that putting one band on-axis would not have much effect on this. That's because refocusing optics are needed for other reasons -- in particular, to keep the horn size reasonable -- and it is those optics that dominate the beam squint, not the offset of the whole assembly from the axis of the main reflector. The refocusing is done with a pair of offset mirrors for most bands. It might conceivably be done with an on-axis lens, thereby avoiding beam squint, but above about 200 GHz this would introduce excessive loss and would limit the bandwidth. 3. As you say, there will be significant variation of the antenna's polarization state across the beam no matter what we do with the optics, and this variation will require calibration. This fact makes it much less important that the design strive to make the variation as small as possible. Your point regarding the time stability of the polarization pattern is well taken. This is only one of several reasons that the optics must be stable and reproducible, and achieving this is a major goal of the design. We believe that a very high degree of polarization stability will be achieved for a given receiver assembly at any fixed frequency, in the sense that changes will be undetectable by any astronomical calibration. However, we are uncertain how reproducible the polarization will be when an entire front end assembly or a band-specific cartridge is swapped out. The biggest problem with wide-field polarization imaging is something that you did not address: even if the polarization of each antenna's beam is perfectly known (calibrated), it is not straightforward to apply this information to the raw visibilities so as to produce accurate images of the polarized radiation. Only under the assumptions that the polarization state is constant across the beams and identical among the antennas does this become tractable. 4. The lack of understanding of the calibration process by the astronomers makes it difficult for them to provide useful design feedback to the engineers. Most of the literature concerns methods usable on existing instruments like the VLA. But ALMA is a new instrument, and it can have new features. Darrel's explanation of the subreflector-mounted cal source is an example of this. Yet its significance should not be overstated. It provides a signal that is strongly phase-coherent between the two polarization channels of the same antenna, unlike any natural source, and this is its value for polarization work. But it does this at a single frequency (albeit sweepable) rather than across the broad bandwidth of a continuum observation, so it is not the answer to all problems. 5. The TI will certainly be operated in polarization modes. That is, the correlator will be able to compute cross-correlations of opposite polarizations in single-dish observations as well as cross-polarized baselines in interferometry (although not all at the same time). This should enable us to try out various calibration techniques. However, it should be recognized that the front end optics of the evaluation receivers will be very different from those of the array receivers. Eventually, when the prototype array receivers are available, it may be possible to test them in the TI, but this is far enough in the future that the details are rather sketchy at present. It is almost impossible for any polarization experiments done with the TI to have any effect on the contract for the production antennas, but it is also hard to see how anything in that contract can have a significant effect on the polarization performance of the array. --Larry D'Addario