Responsible: Effland

***************************************************************************************

RID 1683

Doc. Title
Band 6 design Report Originator: Stephane Claude Date: 2007-09-11

Description:
P93-94, the mass budget presented is done in two different ways. The specification calls

for 2kg maximum therefore Band 6 exceeds the specification by 108g (according to figure

93). That is not what is reported in the compliance matrix P106 section 4.1: specs is

10.6kg (where does this come from?) measured value 14.4kg.
Suggested Solution:
Clarify and refer strictly to the specification.

***************************************************************************************

RID 1685

Doc. Title
Band 6 design Report Originator: Stephane Claude Date: 2007-09-11

Description:
P108 section 5.4.2. The comment refers to drop test with the shipping container. This

should be in section 5.5 “storage and shipping condition” and not in the environmental

operating condition section.
Suggested Solution:
Update Matrix

***************************************************************************************

RID 1686

Doc. Title
Band 6 design Report Originator: Stephane Claude Date: 2007-09-11

Description:
P106 section 4.4. spec calls for A, R and T. Analysis has been done with the FEA.
Suggested Solution:
Update Matrix

***************************************************************************************

RID 1709

Doc. Title
Specification, Section 4.3.3 Originator: James Lamb Date: 2007-09-09

Description:
What does 'Each 8 GHz of bandwidth shall be evenly split into upper and lower sidebands

and these shall be centered at 8 GHz' mean? i.e., Two 8-GHz IF bands, with equal system

temperatures, two 4-GHz bands (as opposed to a 2 GHz and a 6 GHz band, ...)
Suggested Solution:

***************************************************************************************

RID 1711

Doc. Title
Specification, Section 5.5 Originator: James Lamb Date: 2007-09-09

Description:
What does the notation 'sigma^2(2, T, 0.9*T)' mean?

What is the input to the cartridge for this measurement (300 K load, 77 K load)?
Suggested Solution:
-------------------------------------------------------------------------------------------------------------
Printed 2007-09-18 16:52:28 Page 3 of 8
First Previous Next Last