| | CDR RIDS |
| Responsible: Effland |
| | *************************************************************************************** |
| | RID 230 |
| | Doc. Title | | Band 6 Cartridge Design Report | Originator: Hans Rudolf | Date: 2007-08-31 |
| | Description: | | 7.1.2 Changes in Optics with temperature (Page 27): Does the compensation also include |
| | changes of the ellipiticity due to thermal contraction? |
| Suggested Solution: |
| | *************************************************************************************** |
| | RID 1666 |
| | Doc. Title | | Cross Polarization | Originator: Yutaro Sekimoto | Date: 2007-09-10 |
| | Description: | | FEND-40.02.06.00-060-D-DSN, FEND-40.02.06.01-035-A-PRO, FEND-40.02.06.01-020-B- |
| | PRO |
| | |
| | Cross polarization is higher than specification. Because the phase was measured as FEND- |
| | 40.02.06.01-021-B-PRO, it can be converted to far field. It seems better to check |
| | compliance for the new specification of [FEND-40.00.00.00-00226-00 / AT] "The |
| | polarization efficiency of the tertiary optics system shall exceed 99.5 %" in ALMA- |
| | 40.00.00.00-001-A-SPE. |
| Suggested Solution: | | Comparison between simulation and measurement of optical components (horn, horn + |
| | OMT, horn + Optics block) may be useful for solving this discrepancy. |
| | *************************************************************************************** |
| | RID 1667 |
| | Doc. Title | | Vacuum Requirement | Originator: Yutaro Sekimoto | Date: 2007-09-10 |
| | Description: | | I can not find compliance status for outgassing requirements of TML and CVCM in vacuum |
| | requirements ALMA-40.03.00.00-015-A-SPE. |
| Suggested Solution: |
| | *************************************************************************************** |
| | RID 1671 |
| | Doc. Title | | Interface Control Document between | Originator: Shin’ichiro Asayama | Date: 2007-09-10 |
| | Front End Band 6 Cartridge and Front End |
| | IF Switch |
| | Description: | | IF specification should be defined with 4 GHz bandwidth (6 to 10 GHz). |
| Suggested Solution: |
| ------------------------------------------------------------------------------------------------------------- |
| Printed 2007-09-18 16:52:12 | Page 1 of 8 |