pipeline.hif.tasks.makeimlist package

Submodules

pipeline.hif.tasks.makeimlist.cleantarget module

class pipeline.hif.tasks.makeimlist.cleantarget.CleanTarget(*args, **kwargs)[source]

Bases: dict

Clean target template definition.

pipeline.hif.tasks.makeimlist.makeimlist module

class pipeline.hif.tasks.makeimlist.makeimlist.MakeImList(inputs)[source]

Bases: pipeline.infrastructure.basetask.StandardTaskTemplate

Inputs

alias of MakeImListInputs

analyse(result)[source]

Determine the best parameters by analysing the given jobs before returning any final jobs to execute.

Parameters

jobs (a list ofJobRequest) – the job requests generated by prepare()

Return type

Result

is_multi_vis_task = True
prepare()[source]

Prepare job requests for execution.

Parameters

parameters – the parameters to pass through to the subclass. Refer to the implementing subclass for specific information on what these parameters are.

Return type

a class implementing Result

class pipeline.hif.tasks.makeimlist.makeimlist.MakeImListInputs(context, output_dir=None, vis=None, imagename=None, intent=None, field=None, spw=None, contfile=None, linesfile=None, uvrange=None, specmode=None, outframe=None, hm_imsize=None, hm_cell=None, calmaxpix=None, phasecenter=None, nchan=None, start=None, width=None, nbins=None, robust=None, uvtaper=None, clearlist=None, per_eb=None, calcsb=None, parallel=None, known_synthesized_beams=None)[source]

Bases: pipeline.infrastructure.vdp.StandardInputs

calcsb

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

calmaxpix

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

clearlist

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

contfile

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

field

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

get_spw_hm_cell(spwlist)[source]

If possible obtain spwlist specific hm_cell, otherwise return generic value.

hif_checkproductsize() task determines the mitigation parameters. It does not know, however, about the set spwlist in the hif_makeimlist call and determines mitigation parameters per band (complete spw set). The band containing the set spwlist is determined by checking whether spwlist is a subset of the band spw list. The mitigation parameters found for the matching band are applied to the set spwlist.

If no singluar band (spw set) is found that would contain spwlist, then the default hm_cell heuristics is returned.

TODO: refactor and make hif_checkproductsize() (or a new task) spwlist aware.

get_spw_hm_imsize(spwlist)[source]

If possible obtain spwlist specific hm_imsize, otherwise return generic value.

TODO: refactor and make hif_checkproductsize() (or a new task) spwlist aware.

hm_cell

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

hm_imsize

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

imagename

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

intent

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

linesfile

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

nbins

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

nchan

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

outframe

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

parallel

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

per_eb

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

phasecenter

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

specmode

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

spw

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

start

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

uvrange

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

width

VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.

On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:

  1. If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.

  2. If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.

  3. The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.

A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.

A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.

Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,

solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])

pipeline.hif.tasks.makeimlist.qa module

class pipeline.hif.tasks.makeimlist.qa.MakeImListListQAHandler[source]

Bases: pipeline.infrastructure.pipelineqa.QAPlugin

child_cls

alias of pipeline.hif.tasks.makeimlist.resultobjects.MakeImListResult

handle(context, result)[source]
result_cls

alias of collections.abc.Iterable

class pipeline.hif.tasks.makeimlist.qa.MakeImListQAHandler[source]

Bases: pipeline.infrastructure.pipelineqa.QAPlugin

child_cls = None
handle(context, result)[source]
result_cls

alias of pipeline.hif.tasks.makeimlist.resultobjects.MakeImListResult

pipeline.hif.tasks.makeimlist.resultobjects module

class pipeline.hif.tasks.makeimlist.resultobjects.MakeImListResult(error=False, error_msg=None)[source]

Bases: pipeline.infrastructure.basetask.Results

add_target(target)[source]
property max_num_targets
merge_with_context(context)[source]

Merge these results with the given context.

This method will be called during the execution of accept(). For calibration tasks, a typical implementation will register caltables with the pipeline callibrary.

At this point the result is deemed safe to merge, so no further checks on the context need be performed.

Parameters

context (Context) – the target Context

property num_targets
set_info(info)[source]
set_max_num_targets(max_num_targets)[source]

Module contents