pipeline.hif.tasks.setmodel package¶
Submodules¶
pipeline.hif.tasks.setmodel.display module¶
-
class
pipeline.hif.tasks.setmodel.display.
AmpVsUVSummaryChart
(context, output_dir, calto, intent='', ydatacolumn='model', **overrides)[source]¶ Bases:
pipeline.hif.tasks.setmodel.display.BasebandSummaryChart
Create an amplitude vs UV distance plot for each baseband.
-
class
pipeline.hif.tasks.setmodel.display.
BasebandComposite
(context, output_dir, calto, xaxis, yaxis, ant='', field='', intent='', uvrange='', **kwargs)[source]¶ Bases:
pipeline.h.tasks.common.displays.applycal.BasebandComposite
Create a PlotLeaf for each baseband in the applied calibration.
-
class
pipeline.hif.tasks.setmodel.display.
BasebandSummaryChart
(context, output_dir, calto, xaxis, yaxis, intent, **kwargs)[source]¶ Bases:
pipeline.hif.tasks.setmodel.display.PlotmsBasebandComposite
Base class for executing plotms per baseband
-
class
pipeline.hif.tasks.setmodel.display.
PlotmsBasebandComposite
(context, output_dir, calto, xaxis, yaxis, ant='', field='', intent='', uvrange='', **kwargs)[source]¶ Bases:
pipeline.hif.tasks.setmodel.display.BasebandComposite
-
leaf_class
¶ alias of
pipeline.h.tasks.common.displays.applycal.PlotmsLeaf
-
pipeline.hif.tasks.setmodel.qa module¶
-
class
pipeline.hif.tasks.setmodel.qa.
SetModelsListQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
QA handler for a list containing FluxCalibrationResults.
-
child_cls
¶ alias of
pipeline.h.tasks.common.commonfluxresults.FluxCalibrationResults
-
generating_task
¶
-
result_cls
¶ alias of
collections.abc.Iterable
-
-
class
pipeline.hif.tasks.setmodel.qa.
SetModelsQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
-
child_cls
= None¶
-
generating_task
¶
-
result_cls
¶ alias of
pipeline.h.tasks.common.commonfluxresults.FluxCalibrationResults
-
-
class
pipeline.hif.tasks.setmodel.qa.
SetjyListQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
QA handler for a list containing FluxCalibrationResults.
-
child_cls
¶ alias of
pipeline.h.tasks.common.commonfluxresults.FluxCalibrationResults
-
generating_task
¶
-
result_cls
¶ alias of
collections.abc.Iterable
-
-
class
pipeline.hif.tasks.setmodel.qa.
SetjyQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
-
child_cls
= None¶
-
generating_task
¶
-
result_cls
¶ alias of
pipeline.h.tasks.common.commonfluxresults.FluxCalibrationResults
-
pipeline.hif.tasks.setmodel.renderer module¶
Created on 11 Sep 2014
@author: sjw
-
class
pipeline.hif.tasks.setmodel.renderer.
FluxTR
(vis, field, spw, freq, band, i, q, u, v, spix, fluxcsv)¶ Bases:
tuple
-
property
band
¶ Alias for field number 4
-
property
field
¶ Alias for field number 1
-
property
fluxcsv
¶ Alias for field number 10
-
property
freq
¶ Alias for field number 3
-
property
i
¶ Alias for field number 5
-
property
q
¶ Alias for field number 6
-
property
spix
¶ Alias for field number 9
-
property
spw
¶ Alias for field number 2
-
property
u
¶ Alias for field number 7
-
property
v
¶ Alias for field number 8
-
property
vis
¶ Alias for field number 0
-
property
-
class
pipeline.hif.tasks.setmodel.renderer.
T2_4MDetailsSetjyRenderer
(uri='setjy.mako', description='Set calibrator model visibilities', always_rerender=False)[source]¶ Bases:
pipeline.infrastructure.renderer.basetemplates.T2_4MDetailsDefaultRenderer
pipeline.hif.tasks.setmodel.setjy module¶
-
class
pipeline.hif.tasks.setmodel.setjy.
Setjy
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
SetjyInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
-
class
pipeline.hif.tasks.setmodel.setjy.
SetjyInputs
(context, output_dir=None, vis=None, field=None, intent=None, spw=None, model=None, scalebychan=None, fluxdensity=None, spix=None, reffreq=None, standard=None, refspectra=None, reffile=None, normfluxes=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
field
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
fluxdensity
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
intent
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
normfluxes
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
reffile
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
reffreq
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
refspectra
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
scalebychan
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
spix
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
standard
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
pipeline.hif.tasks.setmodel.setmodel module¶
-
class
pipeline.hif.tasks.setmodel.setmodel.
SetModels
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
SetModelsInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
-
class
pipeline.hif.tasks.setmodel.setmodel.
SetModelsInputs
(context, output_dir=None, vis=None, reference=None, refintent=None, transfer=None, transintent=None, reffile=None, normfluxes=None, scalebychan=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
normfluxes
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
reference
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
reffile
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
refintent
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
scalebycan
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
transfer
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
transintent
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-