pipeline.hsd.tasks.baseline package¶
Submodules¶
pipeline.hsd.tasks.baseline.baseline module¶
-
class
pipeline.hsd.tasks.baseline.baseline.
DeviationMaskHeuristicsTask
(heuristics_cls, vis, field_list, antenna_list, spw_list, consider_flag=False)[source]¶
-
class
pipeline.hsd.tasks.baseline.baseline.
HeuristicsTask
(heuristics_cls, *args, **kwargs)[source]¶ Bases:
object
-
class
pipeline.hsd.tasks.baseline.baseline.
SDBaseline
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
SDBaselineInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
static
evaluate_deviation_mask
(vis, field_id, antenna_id, spw_id, consider_flag=False)[source]¶ Create deviation mask using MaskDeviation heuristic
-
is_multi_vis_task
= True¶
-
-
class
pipeline.hsd.tasks.baseline.baseline.
SDBaselineInputs
(context, infiles=None, antenna=None, spw=None, pol=None, field=None, linewindow=None, linewindowmode=None, edge=None, broadline=None, fitorder=None, fitfunc=None, switchpoly=None, clusteringalgorithm=None, deviationmask=None, parallel=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
Inputs for baseline subtraction
-
broadline
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
clusteringalgorithm
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
deviationmask
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
edge
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
field
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
fitfunc
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
fitorder
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
infiles
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
linewindow
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
linewindowmode
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
parallel
¶
-
pol
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
spw
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
switchpoly
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
to_casa_args
()[source]¶ Express these inputs as a dictionary of CASA arguments. The values in the dictionary are in a format suitable for CASA and can be directly passed to the CASA task.
- Return type
a dictionary of string/??? kw/val pairs
-
vis
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
-
class
pipeline.hsd.tasks.baseline.baseline.
SDBaselineResults
(task=None, success=None, outcome=None)[source]¶
pipeline.hsd.tasks.baseline.detection module¶
-
class
pipeline.hsd.tasks.baseline.detection.
DetectLine
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
DetectLineInputs
-
LineFinder
¶ alias of
pipeline.h.heuristics.linefinder.HeuristicsLineFinder
-
ThresholdFactor
= 3.0¶
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
-
class
pipeline.hsd.tasks.baseline.detection.
DetectLineInputs
(context, group_id=None, window=None, windowmode=None, edge=None, broadline=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
broadline
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
edge
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
window
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
windowmode
¶
-
-
class
pipeline.hsd.tasks.baseline.detection.
DetectLineResults
(task=None, success=None, outcome=None)[source]¶ Bases:
pipeline.hsd.tasks.common.common.SingleDishResults
-
merge_with_context
(context)[source]¶ Merge these results with the given context.
See the documenetation of super class for more details.
-
property
signals
¶
-
-
class
pipeline.hsd.tasks.baseline.detection.
LineWindowParser
(ms, window)[source]¶ Bases:
object
LineWindowParser is a parser for line window parameter. Supported format is as follows:
- [Single window list] – apply to all spectral windows
integer list [chmin, chmax]
float list [fmin, fmax]
string list [‘XGHz’, ‘YGHz’]
- [Multiple window list] – apply to all spectral windows
nested integer list [[chmin, chmax], [chmin, chmax], …]
nested float list [[fmin, fmax], [fmin, fmax], …]
nested string list [[‘XGHz’, ‘YGHz’], [‘aMHz’, ‘bMHz’], …]
- [Dictionary] – apply to selected spectral windows
{<spwid>: <window list>} style dictionary
spwid should be an integer specifying spectral window id
window list should be in one of the above list-type window formats
- [MS channel selection syntax] – apply to selected spectral windows
channel selection string ‘A:chmin~chmax;chmin~chmax,B:fmin~fmax,…’
Note that frequencies are interpreted as the value in LSRK frame. Note also that frequencies given as a floating point number is interpreted as the value in Hz.
pipeline.hsd.tasks.baseline.display module¶
-
class
pipeline.hsd.tasks.baseline.display.
ClusterDisplay
(inputs)[source]¶ Bases:
object
-
Inputs
¶ alias of
pipeline.hsd.tasks.common.display.SingleDishDisplayInputs
-
property
context
¶
-
plot
(**kwargs)¶
-
-
class
pipeline.hsd.tasks.baseline.display.
ClusterDisplayWorker
(group_id, iteration, cluster, spw, field, stage_dir)[source]¶ Bases:
object
-
MATPLOTLIB_FIGURE_ID
= 8907¶
-
-
class
pipeline.hsd.tasks.baseline.display.
ClusterPropertyDisplay
(group_id, iteration, cluster, spw, field, stage_dir)[source]¶ Bases:
pipeline.hsd.tasks.baseline.display.ClusterDisplayWorker
-
class
pipeline.hsd.tasks.baseline.display.
ClusterScoreDisplay
(group_id, iteration, cluster, spw, field, stage_dir)[source]¶ Bases:
pipeline.hsd.tasks.baseline.display.ClusterDisplayWorker
-
class
pipeline.hsd.tasks.baseline.display.
ClusterValidationAxesManager
(clusters_to_plot, nh, nv, aspect_ratio, xformatter, yformatter, xlocator, ylocator, xrotation, yrotation, ticksize, labelsize, titlesize)[source]¶ Bases:
pipeline.infrastructure.displays.pointing.MapAxesManagerBase
-
property
axes_legend
¶
-
property
axes_list
¶
-
property
-
class
pipeline.hsd.tasks.baseline.display.
ClusterValidationDisplay
(context, group_id, iteration, cluster, flag_digits, vis, spw, field, antenna, lines, stage_dir, org_direction)[source]¶ Bases:
pipeline.hsd.tasks.baseline.display.ClusterDisplayWorker
-
Description1
= {'detection': 'Clustering Analysis at Detection stage', 'final': 'Clustering Analysis at Final stage', 'smoothing': 'Clustering Analysis at Smoothing stage', 'validation': 'Clustering Analysis at Validation stage'}¶
-
Description2
= {'detection': 'Yellow Square: Single spectrum is detected in the grid\nCyan Square: More than one spectra are detected in the grid\n', 'final': 'Green Square: Final Grid where the line protection channels are calculated and applied to the baseline subtraction\nBlue Square: Final Grid where the calculated line protection channels are applied to the baseline subtraction\n\nIsolated Grids are eliminated.\n', 'smoothing': 'Blue Square: Passed continuity check\nCyan Square: Border\nYellow Square: Questionable\n', 'validation': 'Validation by the rate (Number of clustering member [Nmember] v.s. Number of total spectra belong to the Grid [Nspectra])\n Blue Square: Validated: Nmember > ${valid} x Nspectra\nCyan Square: Marginally validated: Nmember > ${marginal} x Nspectra\nYellow Square: Questionable: Nmember > ${questionable} x Nspectrum\n'}¶
-
pipeline.hsd.tasks.baseline.maskline module¶
-
class
pipeline.hsd.tasks.baseline.maskline.
MaskLine
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
MaskLineInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
-
class
pipeline.hsd.tasks.baseline.maskline.
MaskLineInputs
(context, iteration, group_id, member_list, window=None, windowmode=None, edge=None, broadline=None, clusteringalgorithm=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
broadline
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
clusteringalgorithm
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
edge
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
group_desc
¶
-
property
reference_member
¶
-
window
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
windowmode
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
pipeline.hsd.tasks.baseline.plotter module¶
-
class
pipeline.hsd.tasks.baseline.plotter.
BaselineSubtractionPlotManager
(context, datatable)[source]¶ Bases:
object
-
static
generate_plot_rowlist
(ms_id, antenna_id, spw_id, polarization_ids, grid_table, plot_table, each_plane)[source]¶
-
plot_profile_map_with_fit
(prefit_figfile_prefix, postfit_figfile_prefix, grid_table, deviation_mask, line_range, org_direction, atm_transmission, atm_frequency)[source]¶ plot_table format: [[0, 0, RA0, DEC0, [IDX00, IDX01, …]],
[0, 1, RA0, DEC1, [IDX10, IDX11, …]], …]
-
plot_spectra_with_fit
(**kwargs)¶
-
static
-
class
pipeline.hsd.tasks.baseline.plotter.
PlotterPool
[source]¶ Bases:
object
-
pipeline.hsd.tasks.baseline.plotter.
analyze_plot_table
(ms, ms_id, antid, virtual_spwid, polids, grid_table, org_direction)[source]¶
-
pipeline.hsd.tasks.baseline.plotter.
configure_2d_panel
(xpanel, ypanel, ngridx, ngridy, num_plane=3)[source]¶
-
pipeline.hsd.tasks.baseline.plotter.
get_averaged_data
(infile, dtrows, num_ra, num_dec, num_chan, num_pol, rowlist, rowmap=None, map_data_storage=None, map_mask_storage=None)[source]¶
-
pipeline.hsd.tasks.baseline.plotter.
get_data
(infile, dtrows, num_ra, num_dec, num_chan, num_pol, rowlist, rowmap=None, integrated_data_storage=None, integrated_mask_storage=None, map_data_storage=None, map_mask_storage=None)[source]¶
pipeline.hsd.tasks.baseline.qa module¶
-
class
pipeline.hsd.tasks.baseline.qa.
SDBaselineListQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
-
child_cls
¶ alias of
pipeline.hsd.tasks.baseline.baseline.SDBaselineResults
-
result_cls
¶
-
-
class
pipeline.hsd.tasks.baseline.qa.
SDBaselineQAHandler
[source]¶ Bases:
pipeline.infrastructure.pipelineqa.QAPlugin
-
child_cls
= None¶
-
result_cls
¶ alias of
pipeline.hsd.tasks.baseline.baseline.SDBaselineResults
-
pipeline.hsd.tasks.baseline.renderer module¶
-
class
pipeline.hsd.tasks.baseline.renderer.
SingleDishClusterPlotsRenderer
(context, result, xytitle, plots)[source]¶ Bases:
pipeline.infrastructure.renderer.basetemplates.JsonPlotRenderer
-
class
pipeline.hsd.tasks.baseline.renderer.
T2_4MDetailsSingleDishBaselineRenderer
(template='hsd_baseline.mako', description='Generate Baseline tables and subtract spectral baseline', always_rerender=False)[source]¶ Bases:
pipeline.infrastructure.renderer.basetemplates.T2_4MDetailsDefaultRenderer
pipeline.hsd.tasks.baseline.rules module¶
pipeline.hsd.tasks.baseline.simplegrid module¶
-
class
pipeline.hsd.tasks.baseline.simplegrid.
SDSimpleGridding
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
SDSimpleGriddingInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
grid
(grid_table, datatable_dict)[source]¶ The process does re-map and combine spectrum for each position grid_table format:
- [[IF,POL,0,0,RAcent,DECcent,[[row0,r0,RMS0,index0,ant0],[row1,r1,RMS1,index1,ant1],..,[rowN,rN,RMSN,indexN,antn]]]
- [IF,POL,0,1,RAcent,DECcent,[[row0,r0,RMS0,index0,ant0],[row1,r1,RMS1,index1,ant1],..,[rowN,rN,RMSN,indexN,antn]]]
[IF,POL,M,N,RAcent,DECcent,[[row0,r0,RMS0,index0,ant0],[row1,r1,RMS1,index1,ant1],..,[rowN,rN,RMSN,indexN,antn]]]]
- where row0,row1,…,rowN should be combined to one for better S/N spectra
‘r’ is a distance from grid position
Number of spectra output is len(grid_table)
- OutputTable format:
- [[IF, POL, X, Y, RA, DEC, # of Combined Sp., # of flagged Sp., RMS]
- [IF, POL, X, Y, RA, DEC, # of Combined Sp., # of flagged Sp., RMS]
[IF, POL, X, Y, RA, DEC, # of Combined Sp., # of flagged Sp., RMS]]
Note that IF above is the virtual spw id that should be translated into real spw id when applying to measurementset domain object.
-
-
class
pipeline.hsd.tasks.baseline.simplegrid.
SDSimpleGriddingInputs
(context, group_id, member_list, window, windowmode, nplane=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
property
group_desc
¶
-
nplane
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
reference_member
¶
-
property
windowmode
¶
-
property
pipeline.hsd.tasks.baseline.validation module¶
-
class
pipeline.hsd.tasks.baseline.validation.
SVDSolver2D
(xorder, yorder)[source]¶ Bases:
object
-
CONDITION_NUMBER_LIMIT
= 1e-12¶
-
-
class
pipeline.hsd.tasks.baseline.validation.
ValidateLineInputs
(context, group_id, member_list, iteration, grid_ra, grid_dec, window=None, windowmode=None, edge=None, nsigma=None, xorder=None, yorder=None, broad_component=None, clusteringalgorithm=None)[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
broad_component
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
clusteringalgorithm
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
edge
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
group_desc
¶
-
nsigma
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
reference_member
¶
-
window
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
property
windowmode
¶
-
xorder
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
yorder
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
-
class
pipeline.hsd.tasks.baseline.validation.
ValidateLineRaster
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
CLUSTER_WHITEN
= 1.0¶
-
CheckLineIdentity
(old, new, overlap=0.7)[source]¶ True if the overlap of two lines is greater than the threshold 1L 1R 1L 1R 1L 1R 1L 1R
[ ] [ ] [ ] [ ] xxxxxxxxxxxx xxxxxxxxxxxx xxxxxxxxxxx xxxxxxxxxxx
oooooooooooooo oooooooooooo ooooooooooo ooooooooo [ ] [ ] [ ] [ ] 2L 2R 2L 2R 2L 2R 2L 2R
True if Num(x) / Num(o) >= overlap
old: [left, right, binning] new: [left, right, binning]
-
CleanIsolation
(nra, ndec, Original, Plane, GridMember)[source]¶ Clean isolated cluster return: if no cluster is left after the cleaning, n == 0
MemberList contains positions of cluster member with Marginal+Valid detection MemberList[n]: [[(x00,y00),(x01,y01),……..,(x0k-1,y0k-1)],
- [(x10,y10),(x11,y11),..,(x1i-1,y1i-1)],
[(xn-10,yn-10),(xn-11,yn-11),..,(xn-1i-1,yn-1j-1)]]
Realmember contains positions of cluster member with only Valid detection Realmember[n]: [[(x00,y00),(x01,y01),..,(x0a-1,y0a-1)],
- [(x10,y10),(x11,y11),..,(x1b-1,y1b-1)],
[(xn-10,yn-10),(xn-11,yn-11),..,(xn-1c-1,yn-1c-1)]]
-
DebugOutName
= '61226'¶
-
DebugOutVer
= [0, 0]¶
-
Inputs
¶ alias of
ValidateLineInputs
-
Marginal
= 0.35¶
-
property
MaxFWHM
¶
-
MinFWHM
= 5¶
-
Questionable
= 0.2¶
-
Valid
= 0.5¶
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
calc_ProtectMask
(Center, Width, nchan, MinFWHM, MaxFWHM)[source]¶ return ProtectMask: [MaskL, MaskR]
-
clean_cluster
(Data, Category, Region, Nthreshold, NumParam)[source]¶ - Clean-up cluster by eliminating outliers
Radius = StandardDeviation * nThreshold (circle/sphere)
- in:
Data Category Nthreshold Ncluster
- out:
Region: flag information is added Range: Range[Ncluster][5]: [ClusterCenterX, ClusterCenterY, 0, 0, Threshold] Stdev: Stdev[Ncluster][5]: [ClusterStddevX, ClusterStddevY, 0, 0, 0] Category: renumbered category
-
clean_detect_line
(data, threshold=0.6)[source]¶ Select only line candidates with good possibility by checking all spectra taken at the same position data: {ID1: [[LineStart, LineEnd, Binning],,,],
ID2: [[LineStart, LineEnd, Binning],,,], IDn: [[LineStart, LineEnd, Binning],,,]}
-
clean_detect_signal
(DS)[source]¶ Spectra in each grid positions are splitted into 3 groups along time series. Group of spectra is then combined to 1 spectrum. So, one grid position has 3 combined spectra. Suppose that the real signal is correlated but the error is not, we can clean false signals (not correlated) in advance of the validation stage. detect_signal = {ID1: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannel2, LineEndChannel2, Binning], [LineStartChannelN, LineEndChannelN, Binning]]],
- IDn: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannelN, LineEndChannelN, Binning]]]}
-
clustering_hierarchy
(Region, Region2, nThreshold=3.0, nThreshold2=4.5, method='single')[source]¶ Hierarchical Clustering method = ‘ward’ : Ward’s linkage method
‘single’ : nearest point linkage method ‘complete’: farthest point linkage method ‘average’ : average linkage method ‘centroid’: centroid/UPGMC linkage method ‘median’ : median/WPGMC linkage method
1st threshold is set to nThreshold x stddev(distance matrix) 2nd threshold is set to nThreshold2 x stddev of sub-cluster distance matrix in:
self.Data -> Region2 self.Ndata
- out:
self.Threshold self.Nthreshold self.Category self.Ncluster
-
detection_stage
(Ncluster, nra, ndec, ra0, dec0, grid_ra, grid_dec, category, Region, detect_signal)[source]¶ Region = [[row, chan0, chan1, RA, DEC, flag, Binning],[],[],,,[]] detect_signal = {ID1: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannel2, LineEndChannel2, Binning], [LineStartChannelN, LineEndChannelN, Binning]]],
- IDn: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannelN, LineEndChannelN, Binning]]]}
-
final_stage
(GridCluster, GridMember, Region, Region2, lines, category, grid_ra, grid_dec, broad_component, xorder, yorder, x0, y0, Grid2SpectrumID, index_list, PosList, cluster_flag)[source]¶
-
prepare
(datatable_dict=None, index_list=None, grid_table=None, detect_signal=None)[source]¶ 2D fit line characteristics calculated in Process3 Sigma clipping iterations will be applied if nsigma is positive order < 0 : automatic determination of fitting order (max = 5)
- detect_signal = {ID1: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannel2, LineEndChannel2, Binning], [LineStartChannelN, LineEndChannelN, Binning]]],
- IDn: [RA, DEC, [[LineStartChannel1, LineEndChannel1, Binning],
[LineStartChannelN, LineEndChannelN, Binning]]]}
- lines: output parameter
[LineCenter, LineWidth, Validity] OK: Validity = True; NG: Validity = False
-
set_data
(Observation, ordering='none')[source]¶ - Observation: numpy.array([[val1, val2, val3,..,valN],
- [val1, val2, val3,..,valN],
[val1, val2, val3,..,valN]], numpy.float)
- where N is a max dimensions of parameter space
- ordering: ‘none’ or list of ordering of columns
e.g., ordering=[2,3,1,0] => [col3,col2,col0,col1]
self.Data: Observation data self.NumParam: Number of dimensions to be used for Clustering Analysis self.Factor: Set default Whitening factor (to be 1.0)
-
-
class
pipeline.hsd.tasks.baseline.validation.
ValidateLineResults
(task=None, success=None, outcome=None)[source]¶
-
class
pipeline.hsd.tasks.baseline.validation.
ValidateLineSinglePointing
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
Inputs
¶ alias of
ValidateLineInputs
-
analyse
(result)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
prepare
(datatable_dict=None, index_list=None, grid_table=None, detect_signal=None)[source]¶ ValidateLine class for single-pointing or multi-pointing (collection of fields with single-pointing). Accept all detected lines without clustering analysis.
- detect_signal = {ID1: [RA, DEC, [[LineStartChannel1, LineEndChannel1],
[LineStartChannel2, LineEndChannel2], [LineStartChannelN, LineEndChannelN]]],
- IDn: [RA, DEC, [[LineStartChannel1, LineEndChannel1],
[LineStartChannelN, LineEndChannelN]]]}
- lines: output parameter
[LineCenter, LineWidth, Validity] OK: Validity = True; NG: Validity = False
-
pipeline.hsd.tasks.baseline.worker module¶
-
class
pipeline.hsd.tasks.baseline.worker.
BaselineSubtractionInputsBase
[source]¶ Bases:
pipeline.infrastructure.vdp.StandardInputs
-
DATACOLUMN
= {'CORRECTED_DATA': 'corrected', 'DATA': 'data', 'FLOAT_DATA': 'float_data'}¶
-
colname
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
-
class
pipeline.hsd.tasks.baseline.worker.
BaselineSubtractionResults
(task=None, success=None, outcome=None)[source]¶
-
class
pipeline.hsd.tasks.baseline.worker.
BaselineSubtractionWorker
(inputs)[source]¶ Bases:
pipeline.infrastructure.basetask.StandardTaskTemplate
-
abstract property
Heuristics
¶ A reference to the
Heuristics
class.
-
Inputs
¶ alias of
BaselineSubtractionWorkerInputs
-
analyse
(results)[source]¶ Determine the best parameters by analysing the given jobs before returning any final jobs to execute.
- Parameters
jobs (a list of
JobRequest
) – the job requests generated byprepare()
- Return type
Result
-
is_multi_vis_task
= False¶
-
abstract property
-
class
pipeline.hsd.tasks.baseline.worker.
BaselineSubtractionWorkerInputs
(context, vis=None, plan=None, fit_order=None, switchpoly=None, edge=None, deviationmask=None, blparam=None, bloutput=None, org_directions_dict=None)[source]¶ Bases:
pipeline.hsd.tasks.baseline.worker.BaselineSubtractionInputsBase
-
antenna
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
bloutput
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
blparam
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
channelmap_range
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
deviationmask
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
edge
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
field
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
fit_order
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
grid_table
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
org_directions_dict
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
plan
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
prefix
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
spw
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
switchpoly
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
vis
¶ VisDependentProperty is a Python data descriptor that standardises the behaviour of pipeline Inputs properties and lets them create default values more easily.
On reading a VisDependentProperty (ie. using the dot prefix: inputs.solint), one of two things happens:
If a NullMarker is found - signifying that no user input has been provided - and a ‘getter’ function has been defined, the getter function will be called to provide a default value for that measurement set.
If a user has overridden the value (eg. inputs.solint = 123), that value will be retrieved.
The value, either the default from step 1 or user-provided from step 2, is run through the optional postprocess function, which gives a final opportunity to change the value depending on the state/value of other properties.
A VisDependentProperty can be made read-only by specifying ‘readonly=True’ when creating the instance.
A VisDependentProperty can be hidden from the containing Inputs string representation by setting ‘hidden=True’ when creating the instance. This will hide the property from the web log and CLI getInputs calls.
Each VisDependentProperty has a set of values it considers equivalent to null. When the user sets the VDP value to one of these null values, the VDP machinery converts this to a private NullObject marker that signifies the property is now unset, resulting in the default value being returned next time the property is read. Developers can specify which values should be converted to NullObject by specifying null_input at creation time, e.g.,
solint = @VisDependentProperty(default=5, null_input=[None, ‘’, ‘RESET’, -1])
-
-
class
pipeline.hsd.tasks.baseline.worker.
CubicSplineBaselineSubtractionWorker
(inputs)[source]¶ Bases:
pipeline.hsd.tasks.baseline.worker.BaselineSubtractionWorker
-
Heuristics
¶ alias of
pipeline.hsd.heuristics.baselineparamconfig.CubicSplineFitParamConfig
-
Inputs
¶ alias of
BaselineSubtractionWorkerInputs
-
-
class
pipeline.hsd.tasks.baseline.worker.
HpcBaselineSubtractionWorker
(inputs)[source]¶ Bases:
pipeline.infrastructure.sessionutils.ParallelTemplate
-
Inputs
¶ alias of
HpcBaselineSubtractionWorkerInputs
-
get_result_for_exception
(*args, **kw)¶
-
-
class
pipeline.hsd.tasks.baseline.worker.
HpcBaselineSubtractionWorkerInputs
(context, vis=None, plan=None, fit_order=None, switchpoly=None, edge=None, deviationmask=None, blparam=None, bloutput=None, parallel=None, org_directions_dict=None)[source]¶ Bases:
pipeline.hsd.tasks.baseline.worker.BaselineSubtractionWorkerInputs
-
property
parallel
¶
-
property
-
class
pipeline.hsd.tasks.baseline.worker.
HpcCubicSplineBaselineSubtractionWorker
(inputs)[source]¶ Bases:
pipeline.hsd.tasks.baseline.worker.HpcBaselineSubtractionWorker
-
Task
¶ alias of
CubicSplineBaselineSubtractionWorker
-